{"product_id":"icp-2-pole-30a-contactor-for-rhs102l0ba0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHS102L0BA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite-purpose contactor is the switching relay that sends line voltage to the compressor and condenser fan on your ICP (Tempstar \/ Heil \/ Comfortmaker) RHS102L0BA0AAAA heat pump. When the thermostat calls, a 24V signal energizes the coil and pulls the contacts closed to start the outdoor unit. Rated for 30A and 40A loads with a 24-volt coil, it is built to handle the high inrush of compressor start-up across thousands of cycles. Typical failure symptoms include a humming or chattering condenser, contacts welded closed so the unit won't shut off, pitted or burned contacts, or an outdoor unit that won't start even when the air handler runs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Numbers\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered for the ICP RHS102L0BA0AAAA heat pump and the matching Tempstar, Heil, and Comfortmaker condensers built on the same platform. Verify your existing contactor's pole count and amp\/coil rating before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker; verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note wire positions, pull the spade connectors, and unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor\/fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud humming, buzzing, or chattering from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts visibly pitted, burned, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs continuously and won't shut off\u003c\/li\u003e\n\u003cli\u003eCompressor and fan won't start despite a thermostat call\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021887062387,"sku":"1178074-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047929758067,"sku":"1178074","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_becd4fb1-a564-465d-b802-01ac68547934.jpg?v=1782881107","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhs102l0ba0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}