{"product_id":"icp-2-pole-30a-contactor-for-rhs072h0xb0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHS072H0XB0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite-purpose contactor (part number 1178074) is the primary switching relay for the ICP RHS072H0XB0AAAA heat pump condensing unit. Rated for 30 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor each time the thermostat calls for cooling or heating. When the coil receives 24V from the control board, the contactor pulls in and closes its line-voltage contacts to power the outdoor unit. A failing contactor is one of the most common causes of a no-cool\/no-heat outdoor unit — symptoms include a unit that hums but won't start, chattering at the contactor, pitted or welded contacts, or a fan and compressor that fail to energize even with a valid 24V signal.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor, 2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistive Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory replacement for the ICP RHS072H0XB0AAAA heat pump. Because it is a standard 2-pole, 30A, 24V definite-purpose contactor, it also services many comparable Heil, Tempstar, Comfortmaker, and Day \u0026amp; Night condensing units of similar capacity. Always confirm amperage and coil voltage against the contactor in your unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal location before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note line, load, and coil (24V) wiring, then transfer wires one at a time to the new contactor, or remove all wires and unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to its matching terminal per your photos, and confirm the 24V coil leads are secure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contactor pulls in cleanly and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor\/fan won't start\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eChattering or rapid clicking at the contactor\u003c\/li\u003e\n\u003cli\u003eContactor fails to pull in even with a confirmed 24V signal at the coil\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021903053171,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047929069939,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_5aaac122-c4a4-4ac7-a374-805d5fabc836.jpg?v=1782881064","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhs072h0xb0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}