{"product_id":"icp-2-pole-30a-contactor-for-rhs036l0xb0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHS036L0XB0AAAA – 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM 2-pole, 30-amp definite-purpose contactor (part #1178074) with a 24-volt control coil for the ICP \/ Tempstar \/ Heil RHS036L0XB0AAAA heat pump. The contactor is the electrically operated switch that powers the compressor and outdoor fan motor. When the thermostat calls, 24V energizes the coil, pulling the contacts closed and sending line voltage to the compressor and condenser fan. Over years of cycling, the silver contacts pit, burn, and weld, while the coil can fail open — causing no-start, chattering, or a unit that won't shut off because contacts have welded together. A 30A 2-pole contactor is one of the most common condensing-unit failures and a fast, inexpensive fix.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRHS036L0XB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the RHS036L0XB0AAAA 3-ton R-410A heat pump and other ICP-family condensing units specifying a 2-pole 30A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your old contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the disconnect and breaker; verify zero voltage across the line terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the condensing unit electrical service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer wires one at a time to the new contactor, or label and remove, then unscrew the old contactor from its base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor and reconnect each wire exactly per your photo (line in, compressor\/fan out, 24V to coil).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and confirm the contactor pulls in on a call and the compressor and fan start cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompressor and fan won't start despite a thermostat call\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burnt, or welded contacts\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off (contacts stuck closed)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021928186227,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047927660915,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_e229218d-9577-43f7-b409-6ba66db4d018.jpg?v=1782880985","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhs036l0xb0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}