{"product_id":"icp-2-pole-30a-contactor-for-rhs036l0xa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHS036L0XA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine ICP 2-pole definite-purpose contactor (OEM part 1178074) is the electromechanical switch that energizes your outdoor condensing unit. Rated for 30 amps with a 24-volt control coil, it receives the low-voltage call from your thermostat or control board and closes its contacts to send line voltage to the compressor and condenser fan motor. When a contactor fails, the system either won't start at all or the contacts weld shut and the unit runs continuously. Pitted, burned, or chattering contacts are the most common cause of a no-cooling service call on this equipment.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct OEM replacement for ICP\/Heil\/Tempstar\/Comfortmaker model RHS036L0XA0AAAA and many related condensing units and heat pumps that use a 2-pole, 30A, 24V-coil contactor. Always confirm the coil voltage and amp rating against the part you are removing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect line, load, and 24V coil leads; unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start even though the thermostat is calling for cooling.\u003c\/li\u003e\n\u003cli\u003eBuzzing, humming, or chattering noise from the contactor.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contacts.\u003c\/li\u003e\n\u003cli\u003eUnit runs nonstop because the contacts have welded closed.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63021928218995,"sku":"1178074-GEN","price":26.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047927628147,"sku":"1178074","price":35.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_4f955826-6168-406e-9046-66275518adb1.jpg?v=1782880983","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhs036l0xa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}