{"product_id":"icp-2-pole-30a-contactor-for-rhh090h0ba0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHH090H0BA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite purpose contactor (part number 1178074) for the ICP \/ Tempstar \/ Heil RHH090H0BA0AAAA heat pump. Rated for 30 amps with a 24-volt control coil, the contactor is the electromechanical switch that closes the high-voltage circuit to the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. When the 24V coil energizes, it pulls the contacts closed and sends line voltage to the outdoor unit. A failed contactor is one of the most common reasons an outdoor unit won't start, hums without running, or short-cycles. Pitted, burned, or welded contacts cause intermittent operation, chattering, and eventual compressor failure.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned for the ICP\/Tempstar\/Heil RHH090H0BA0AAAA and other ICP-family heat pump and condensing units using a 2-pole 30A 24V coil contactor. Always confirm pole count, amp rating, and coil voltage against the contactor you are removing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical panel cover on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line and load wiring plus the 24V coil leads before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note wire positions, disconnect each lead, and unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in on a thermostat call and the unit starts cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan won't start\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded-together contacts\u003c\/li\u003e\n\u003cli\u003eUnit short-cycles or runs intermittently\u003c\/li\u003e\n\u003cli\u003eLoud chattering at the contactor when cooling is called\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027263111539,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047926841715,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_dacb3159-f28a-499b-a271-b8b9ba70475f.jpg?v=1782880927","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhh090h0ba0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}