{"product_id":"icp-2-pole-30a-contactor-for-rhh048l0ca0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RHH048L0CA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole, 30 amp contactor (part 1178074) with a 24V coil is the high-voltage switch that powers the compressor and condenser fan on the ICP \/ Heil \/ Tempstar RHH048L0CA0AAAA heat pump. When the thermostat sends a 24V signal, the coil pulls the contacts closed and feeds line voltage to the outdoor unit. Pitted, welded, or chattering contacts are a leading cause of a unit that won't start, hums but won't engage, or trips the breaker. A worn contactor is one of the cheapest and most common fixes for a no-cool \/ no-heat heat pump.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP \/ Heil \/ Tempstar RHH048L0CA0AAAA heat pump and other RHH048 condensing units using a 2-pole 30A \/ 24V contactor. Confirm pole count, amperage, and coil voltage against the old part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control-box service panel on the condenser.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label them, then unbolt the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each lead to match your photos exactly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling\/heating, and confirm the contacts pull in cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but compressor and fan won't start\u003c\/li\u003e\n\u003cli\u003eContacts are pitted, burned, or welded together\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering at the contactor on a call\u003c\/li\u003e\n\u003cli\u003eUnit trips the breaker or starts intermittently\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027265208691,"sku":"1178074-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047926219123,"sku":"1178074","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_93581962-4af1-4996-ba15-abb7fc94ffa7.jpg?v=1782880883","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rhh048l0ca0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}