{"product_id":"icp-2-pole-30a-contactor-for-rgs303srfa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS303SRFA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM 2-pole, 30-amp contactor (part number 1171554) is the electrical switch that energizes the compressor and condenser fan on ICP, Heil, and Tempstar systems associated with the RGS303SRFA0AAAA. A 24-volt coil pulls in the contactor when the thermostat calls for cooling, closing two sets of heavy-duty silver-alloy contacts that pass line voltage to the outdoor unit. Because it cycles every time the system runs, the contactor is a high-wear component and a frequent cause of no-cool service calls.\u003c\/p\u003e\n\u003cp\u003eOver time the contacts pit, burn, and arc, leaving the system unable to start reliably or causing it to stick on and run continuously. A failed coil will prevent pull-in entirely, while welded contacts can keep the compressor energized even when the thermostat is satisfied. Replacing the contactor with the correct OEM 30A \/ 24V part restores clean, dependable switching and protects the compressor from low-voltage and chatter damage.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePole Configuration\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDesigned as a direct replacement for the RGS303SRFA0AAAA and other ICP \/ Heil \/ Tempstar \/ Comfortmaker units calling for the 1171554 2-pole 30A contactor with a 24V coil. Verify the amperage, pole count, and coil voltage against your existing contactor before ordering.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing-unit electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, then unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm the 24V coil leads are correct.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contactor pulls in cleanly and the compressor and fan start without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuzzing or chattering at the contactor during a cooling call\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eCompressor and fan that will not start even with 24V at the coil\u003c\/li\u003e\n\u003cli\u003eOutdoor unit that runs continuously and will not shut off\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027270812019,"sku":"1171554-GEN","price":29.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047925563763,"sku":"1171554","price":37.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_dd5f0c11-3c98-4c31-8f72-5cf243fea173.jpg?v=1782880839","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs303srfa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}