{"product_id":"icp-2-pole-30a-contactor-for-rgs303hrea0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS303HREA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole 30A contactor (part number 1171554) is the switching relay that energizes the high-voltage load on the ICP \/ Tempstar \/ Heil RGS303HREA0AAAA system. When the 24V coil is energized by the control circuit, the contactor closes its 30-amp poles to deliver line power. A larger 3-pole 60A contactor (1183142) is available for higher-load configurations. Contactor failure shows up as pitted or welded contacts, a chattering coil, or no power passing through when the system calls — leaving the unit unable to run. Pitting from arcing is a normal wear pattern that makes contactors a routine maintenance replacement.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554 (2P 30A), 1183142 (3P 60A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole (3-Pole option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amp (60 Amp option)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eCondenser \/ Compressor Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP \/ Tempstar \/ Heil RGS303HREA0AAAA and parts-compatible units using a 2-pole 30A 24V-coil contactor. For higher-amperage applications, select the 3-pole 60A version (1183142). Confirm pole count, amp rating, and 24V coil before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the unit's electrical-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph the line, load, and coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label them, then unscrew and remove the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for operation, and confirm the contactor pulls in cleanly and passes voltage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBurned, pitted, or welded contact points.\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering coil that won't pull in fully.\u003c\/li\u003e\n\u003cli\u003eSystem won't start despite a valid 24V call.\u003c\/li\u003e\n\u003cli\u003eNo line voltage passing through the closed contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027275399539,"sku":"1171554-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047924973939,"sku":"1171554","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_f811f2c5-65bb-476e-8b3b-31a36f438617.jpg?v=1782880796","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs303hrea0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}