{"product_id":"icp-2-pole-30a-contactor-for-rgs243sdfa0aaaa-24v-coil-oem-1171554-ships-today","title":"ICP 2-Pole 30A Contactor for RGS243SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe OEM contactor (part number 1171554) is a 2-pole, 30-amp definite purpose contactor with a 24-volt coil for the ICP Tempstar Heil RGS243SDFA0AAAA system. The contactor is an electrically operated switch — when the thermostat sends a 24V signal to the coil, the contacts close and energize the compressor and condenser fan motor. Over time the contacts pit, burn, and weld from arcing, and the coil can fail, leading to a unit that won't start, chatters, or won't shut off. This genuine OEM 2-pole 30A 24V contactor restores reliable switching.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eContactor, 2P 30A 24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS243SDFA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt as a direct-fit replacement for the ICP Tempstar Heil RGS243SDFA0AAAA system and other ICP-family units that specify OEM part 1171554. This 2-pole 30A 24V-coil contactor is a common configuration across ICP, Tempstar, Heil, and Comfortmaker condensing units. Verify pole count, amperage, and 24V coil match your application before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter before proceeding.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit\/control-box service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, unscrew the contactor from its mount, and remove it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 2-pole 30A contactor, reconnect line, load, and 24V coil leads per your photo, and torque terminals snug.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling. Confirm the coil pulls in, contacts close cleanly, and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser won't start even though the thermostat is calling for cooling.\u003c\/li\u003e\n\u003cli\u003eBuzzing, chattering, or humming from the contactor.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts that stick closed (unit won't shut off).\u003c\/li\u003e\n\u003cli\u003eOpen or burned 24V coil that no longer pulls the contacts in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027286344051,"sku":"1171554-GEN","price":32.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047923597683,"sku":"1171554","price":42.84,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_3effb2f6-3a20-4aa4-b558-060702f09b7e.jpg?v=1782880698","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs243sdfa0aaaa-24v-coil-oem-1171554-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}