{"product_id":"icp-2-pole-30a-contactor-for-rgs240ssfa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS240SSFA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is the genuine OEM 2-pole definite-purpose contactor (OEM part number 1171554) for the ICP\/Heil\/Tempstar RGS240SSFA0AAAA. Rated 30 amps per pole with a 24-volt holding coil, the contactor is the electromechanical switch that energizes the high-voltage load when the 24V control circuit calls for operation. When the thermostat or control board sends 24V to the coil, the magnetic core pulls the contacts closed and power flows to the connected load; when the call ends, the coil de-energizes and a spring opens the contacts. Pitted, welded, or chattering contacts are among the most common failures in HVAC service — they cause hard starts, buzzing, intermittent operation, or a system that will not energize at all.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS240SSFA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered as a direct OEM fit for the ICP RGS240SSFA0AAAA and shared across many Heil, Tempstar, Comfortmaker, and Carrier-family units that use a 2-pole 30A definite-purpose contactor with a 24V coil. Always confirm the original contactor's pole count, amp rating, and coil voltage before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and pull the disconnect; verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect line, load, and 24V coil wires; unscrew the old contactor from its mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in on a call and drop out when satisfied.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor when energized\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eSystem fails to start or runs intermittently\u003c\/li\u003e\n\u003cli\u003eContacts stick closed and the unit will not shut off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027291554163,"sku":"1171554-GEN","price":29.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047922975091,"sku":"1171554","price":38.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_80b93fed-4d9f-4545-89d1-be933fedebd6.jpg?v=1782880655","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs240ssfa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}