{"product_id":"icp-2-pole-30a-contactor-for-rgs214sdaa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS214SDAA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite-purpose contactor (ICP part #1171554) for the ICP\/Tempstar\/Heil RGS214SDAA0AAAA unit. The contactor is the electrically-controlled switch that closes the high-voltage circuit feeding the compressor and condenser fan motor whenever the 24V thermostat call energizes its coil. It is rated for 30 amps per pole with a 24-volt control coil. When a contactor fails, the most common symptoms are a unit that hums but won't start, chattering or buzzing at the contactor, pitted or welded contacts that keep the compressor running continuously, or no outdoor unit operation at all despite a thermostat call. Because the contacts arc every time the system cycles, this is one of the most common wear items in any HVAC system.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct-fit replacement for the ICP\/Tempstar\/Heil\/Comfortmaker RGS214SDAA0AAAA. The 30A\/24V 2-pole configuration is also a common service replacement across many residential condensing units and furnaces using a 24V control circuit. Always confirm pole count, contact amperage, and coil voltage against the part you are removing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter before touching any terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the control area.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line-voltage and 24V coil wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note each wire location, disconnect the line, load, and coil leads, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly as photographed (L1\/L2 line, T1\/T2 load, and the two 24V coil terminals).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, initiate a cooling\/heating call, and confirm the contactor pulls in cleanly with no chatter and the unit starts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud humming or buzzing from the outdoor unit with no startup\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off\u003c\/li\u003e\n\u003cli\u003eIntermittent or no operation when the thermostat calls\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027314295155,"sku":"1171554-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047921893747,"sku":"1171554","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_fa12cc9b-8369-43ac-86ba-d13a80bab0d6.jpg?v=1782880577","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs214sdaa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}