{"product_id":"icp-2-pole-30a-contactor-for-rgs214leaa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS214LEAA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole, 30-amp contactor (part #1171554) is the primary switching relay for the ICP \/ Tempstar \/ Heil RGS214LEAA0AAAA condensing unit. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. Because it cycles on every cooling call, the contactor is one of the most common wear-out items in an outdoor unit. Pitted, welded, or chattering contacts cause hard starts, buzzing, intermittent cooling, or a unit that will not start at all. Replacing a failing contactor restores clean, reliable switching and protects the compressor from voltage spikes.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil RGS214LEAA0AAAA and related RGS214 series condensing units. Verify your existing contactor is a 2-pole, 30A unit with a 24V coil before ordering. Always confirm the part number against your unit's service panel or wiring diagram.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire on the old contactor before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note the line, load, and 24V coil terminals, then transfer wires one at a time to the new contactor to avoid mistakes. Unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to its matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly with no buzzing or chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing or chattering from the outdoor unit on a cooling call\u003c\/li\u003e\n\u003cli\u003eCompressor and fan fail to start, or start intermittently\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contact points\u003c\/li\u003e\n\u003cli\u003eAnts or debris stuck between the contacts preventing closure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027314852211,"sku":"1171554-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047921729907,"sku":"1171554","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_3324fea7-429f-4a64-9a9d-86ee0c6324e4.jpg?v=1782880566","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs214leaa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}