{"product_id":"icp-2-pole-30a-contactor-for-rgs213staa0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS213STAA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite-purpose contactor (part number 1171554) is the primary switching relay for the ICP\/Tempstar\/Heil RGS213STAA0AAAA condensing unit. Rated at 30 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V signal reaches the coil, an electromagnet pulls the contacts closed and sends line voltage to the outdoor equipment. Contactors are one of the most common failure points in an air conditioning system because the contacts arc and pit every time they open and close. Symptoms of a failing contactor include a buzzing or chattering outdoor unit, a compressor that won't start, contacts that weld shut (causing the unit to run continuously), or visible burning and pitting on the contact surfaces.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil RGS213STAA0AAAA. This 2-pole 30A\/24V definite-purpose contactor is also a common replacement across many residential split-system condensing units of similar tonnage that use a 24V control circuit. Always confirm pole count, amp rating, and coil voltage against your original part before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and the breaker. Verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire connections before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Disconnect line, load, and the two 24V coil wires. Unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly as shown in your photo (line in on one side, load to compressor\/fan on the other, 24V to the coil terminals).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and call for cooling. Confirm the contacts pull in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the outdoor unit.\u003c\/li\u003e\n\u003cli\u003eCompressor and fan fail to start on a cooling call.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs nonstop because the contacts have welded closed.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contactor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027316654451,"sku":"1171554-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047921533299,"sku":"1171554","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_bcf53c70-097a-40e5-8a62-ee771e95921c.jpg?v=1782880552","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs213staa0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}