{"product_id":"icp-2-pole-30a-contactor-for-rgs213hdea0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS213HDEA0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM contactor uses a 24-volt control coil to switch line-voltage power to the compressor and condenser fan motor. The reference configuration is a 2-pole, 30-amp contactor (part 1171554), with a heavier 3-pole, 40-amp version (part 1172449) available for higher-load applications. When the thermostat calls, the 24V coil pulls the contacts closed and energizes the outdoor unit; when the call ends, a spring opens the contacts. Over thousands of cycles the silver contacts pit, burn, and can weld shut — leaving the unit running constantly — or fail open so the unit won't start at all. A buzzing or chattering contactor signals a weak coil or low control voltage. Replacing a worn contactor restores clean, reliable switching and protects the compressor from voltage drop.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Part Number\u003c\/td\u003e\n\u003ctd\u003e1171554 (2-Pole, 30A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Part Number\u003c\/td\u003e\n\u003ctd\u003e1172449 (3-Pole, 40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 (or 3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Amps\u003c\/td\u003e\n\u003ctd\u003e30A (or 40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the ICP \/ Heil \/ Tempstar \/ Comfortmaker RGS213HDEA0AAAA and related models using a 24V-coil definite-purpose contactor. Choose the 2-pole 30A (1171554) or 3-pole 40A (1172449) to match your existing contactor's pole count and amp rating before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil connections before removing any wires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Unscrew the old contactor from its bracket and transfer wires one terminal at a time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in cleanly on a cooling call and drops out fully when satisfied.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eLoud buzzing or chattering from the contactor.\u003c\/li\u003e\n\u003cli\u003eBurnt, pitted, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit won't start, or won't shut off.\u003c\/li\u003e\n\u003cli\u003eVisible arcing or melted contactor housing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027323306355,"sku":"1171554-GEN","price":31.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047920583027,"sku":"1171554","price":41.54,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-3pole-1171554_8b0f5f9d-609d-46a2-93fe-20adfa7d3cc6.jpg?v=1782880487","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs213hdea0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}