{"product_id":"icp-2-pole-30a-contactor-for-rgs121leab0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS121LEAB0AAAA – 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM definite-purpose contactor (part #1178074) is a 2-pole, 30 amp device with a 24-volt control coil used in the ICP \/ Heil \/ Tempstar RGS121LEAB0AAAA system. The contactor acts as the high-voltage switch that energizes the compressor and condenser fan motor when the 24V control signal closes the coil. Contactors are high-wear components: the contacts arc every time they pull in, eventually pitting, welding shut, or burning open. A failed contactor is one of the most common causes of a system that won't start, won't shut off, or chatters at the relay.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM exact-fit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the ICP RGS121LEAB0AAAA and shared across ICP-family (Heil, Tempstar, Comfortmaker) equipment using a 2-pole 30A \/ 24V coil contactor. Verify part #1178074 and coil voltage against your unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect all power at the disconnect and breaker. Verify zero voltage on the line terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the electrical\/service panel to expose the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph every wire and terminal position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Label and disconnect line, load, and 24V coil wires; unfasten the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor and reconnect each wire to the matching terminal per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and confirm the contactor pulls in on a call, energizes the load, and releases cleanly when the call ends.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBurned, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor\/fan won't start or won't shut off\u003c\/li\u003e\n\u003cli\u003eBuzzing, humming, or chattering at the contactor\u003c\/li\u003e\n\u003cli\u003eCoil clicks but contacts don't pass voltage to the load\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027494420851,"sku":"1178074-GEN","price":29.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047916552563,"sku":"1178074","price":37.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_041bc6e7-3f6c-42b8-b941-bb4e36085e5e.jpg?v=1782880241","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs121leab0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}