{"product_id":"icp-2-pole-30a-contactor-for-rgs120leca0aaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS120LECA0AAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite purpose contactor (part number 1178074) for the ICP \/ Tempstar \/ Heil RGS120LECA0AAA gas furnace and matched condensing unit. Rated at 30 amps with a 24-volt control coil, the contactor is the high-voltage switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil is energized, the magnetic field pulls the contacts closed, completing the line-voltage circuit to the outdoor unit. A failed or pitted contactor is one of the most common no-cooling service calls — burned, welded, or chattering contacts prevent the compressor from starting, while a failed coil leaves the unit completely unresponsive to the thermostat.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct-fit replacement for the ICP RGS120LECA0AAA and closely related Tempstar, Heil, and Comfortmaker models that share the same 2-pole 30A\/24V contactor platform. Always confirm your existing contactor's amp rating, pole count, and coil voltage against the part you are replacing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line and control wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in and the compressor\/fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but compressor\/fan won't start\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts\u003c\/li\u003e\n\u003cli\u003eChattering or buzzing at the contactor\u003c\/li\u003e\n\u003cli\u003eNo response from the outdoor unit on a cooling call\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027548914035,"sku":"1178074-GEN","price":34.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047914652019,"sku":"1178074","price":45.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_7d06c3af-4351-4978-b1ea-fa2a24b01ae7.jpg?v=1782880147","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs120leca0aaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}