{"product_id":"icp-2-pole-30a-contactor-for-rgs101lsbb0aaaa-24v-coil-oem-relay-ships-today","title":"ICP 2-Pole 30A Contactor for RGS101LSBB0AAAA — 24V Coil OEM Relay | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM 2-pole, 30-amp definite-purpose contactor with a 24-volt control coil (part #1178074) for ICP, Heil, Tempstar and Comfortmaker HVAC equipment associated with the RGS101LSBB0AAAA. The contactor is the high-voltage switch that powers the compressor and condenser fan motor. When the thermostat calls for cooling, 24V is applied to the coil, which pulls in the contacts and energizes the line-voltage circuit. Contactors are a common failure point because the contacts arc and pit with every cycle. Symptoms of a failing 30A contactor include burned or pitted contacts, a humming or chattering coil, contacts that weld closed (so the unit never shuts off), or contacts that no longer pull in (so the unit never starts). Replacing a worn 2-pole contactor restores reliable, clean switching and protects the compressor.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the ICP\/Heil\/Tempstar RGS101LSBB0AAAA and many other ICP-family condensing units and air handlers that use a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating and coil voltage against your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage at the contactor with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and transfer wires one at a time, then unbolt the old contactor from its base.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 2-pole contactor, land each wire exactly as photographed, and verify the 24V coil leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eBurned, pitted or welded contacts\u003c\/li\u003e\n\u003cli\u003eLoud humming, buzzing or chattering coil\u003c\/li\u003e\n\u003cli\u003eSystem won't start (contacts won't close)\u003c\/li\u003e\n\u003cli\u003eSystem won't shut off (contacts stuck closed)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027662029171,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047910883699,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_ed30cb9e-b267-49eb-983e-1a3000eec623.jpg?v=1782879895","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs101lsbb0aaaa-24v-coil-oem-relay-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}