{"product_id":"icp-2-pole-30a-contactor-for-rgs101lrca0aaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS101LRCA0AAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM 2-pole, 30-amp definite purpose contactor, part number 1178074, switches the high-voltage power feeding the compressor and condenser fan motor in the ICP\/Heil\/Tempstar RGS101LRCA0AAA system. A 24V control signal from the thermostat circuit energizes the coil, which pulls the contacts closed and sends line voltage to the outdoor unit. Over time the contact points pit, burn, and weld from repeated arcing, while the coil can fail open. Symptoms of a failing contactor include a humming or chattering outdoor unit, a condenser that won't start, contacts that stick closed so the unit never shuts off, or visible burn marks and pitting on the contact pads. This direct OEM replacement restores reliable, clean switching.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074 (CONTACTOR 2P 30A 24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the ICP\/Heil\/Tempstar RGS101LRCA0AAA and other systems calling for a 2-pole 30A 24V-coil contactor. Match poles, amperage, and coil voltage to your existing part before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser\/electrical service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, then unscrew and remove the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, send a cooling call, and confirm the contacts pull in and the unit starts cleanly.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or chatters but won't start\u003c\/li\u003e\n\u003cli\u003eContacts are pitted, burned, or welded together\u003c\/li\u003e\n\u003cli\u003eSystem won't shut off because contacts are stuck closed\u003c\/li\u003e\n\u003cli\u003eCoil is dead and won't pull the contacts in on a cooling call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027662553459,"sku":"1178074-GEN","price":32.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047910752627,"sku":"1178074","price":41.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_24c0b8c8-5992-4e27-877d-3e05c229c285.jpg?v=1782879886","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs101lrca0aaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}