{"product_id":"icp-2-pole-30a-contactor-for-rgs101ldab0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS101LDAB0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is a genuine OEM 2-pole definite purpose contactor (part number 1178074) for the ICP \/ Tempstar \/ Heil RGS101LDAB0AAAA system. The contactor is an electromagnetic switch: a 24V control signal from the thermostat energizes the coil, which pulls in two sets of power contacts to feed line voltage to the compressor and condenser fan motor. Rated at 30 amps per pole, it switches the highest current loads in the outdoor unit on every cooling cycle. Over time the contacts pit and burn, the coil can open, or the armature can stick — leading to a no-start condition, loud chattering, or a unit that won't shut off. Installing a fresh OEM contactor restores clean, dependable switching and protects the compressor from voltage problems.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS101LDAB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the factory replacement for the ICP \/ Tempstar \/ Heil RGS101LDAB0AAAA system. The 2-pole 30A \/ 24V configuration is also a frequent service replacement across many residential split-system condensers and heat pumps. Verify pole count, amp rating, and coil voltage against your existing contactor before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel to expose the control box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect line, load, and 24V coil leads; unscrew the old contactor from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor or condenser fan will not start on a cooling call\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously and won't shut off after the thermostat is satisfied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027664847219,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047910326643,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_29c2a29d-694d-4f90-8a18-073fb25f3fd3.jpg?v=1782879859","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs101ldab0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}