{"product_id":"icp-2-pole-30a-contactor-for-rgs091sfab0aaaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS091SFAB0AAAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine OEM 2-pole, 30-amp definite purpose contactor with a 24-volt coil for the ICP \/ Heil \/ Tempstar \u003cstrong\u003eRGS091SFAB0AAAA\u003c\/strong\u003e unit, OEM part number \u003cstrong\u003e1178074\u003c\/strong\u003e. The contactor is the high-current switch that energizes the compressor and\/or condenser fan: when the thermostat calls for cooling, the 24V coil pulls the contacts closed and line voltage passes to the load. Over time the contacts pit, arc, and burn, leading to a unit that won't start, chattering, or contacts that weld shut so the system runs continuously. Replacing a worn contactor is one of the most common and important preventive repairs on this equipment.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2 (double-pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS091SFAB0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eA factory-direct fit for the ICP\/Heil\/Tempstar\/Comfortmaker RGS091SFAB0AAAA, and a standard 2-pole 30A 24V coil contactor shared across many ICP-built units. Confirm pole count, amp rating, coil voltage, and your model\/serial tag before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker. Verify zero voltage at the contactor with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical-compartment service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and remove the wires, then unscrew the old contactor from its mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and run a cooling cycle; confirm the contactor pulls in cleanly and the load energizes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eLoud humming, buzzing, or chattering when energized.\u003c\/li\u003e\n\u003cli\u003eCompressor or condenser fan won't start on a cooling call.\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously because contacts are stuck closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027671302515,"sku":"1178074-GEN","price":29.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047909867891,"sku":"1178074","price":38.94,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_192e1804-00de-4918-b12e-3cca3b9b5217.jpg?v=1782879827","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs091sfab0aaaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}