{"product_id":"icp-2-pole-30a-contactor-for-rgs091lraa0aaaa-30-amp-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS091LRAA0AAAA — 30 Amp 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite purpose contactor (part number 1178074) is the switching relay that energizes the compressor and condenser fan motor in your ICP\/Tempstar\/Heil RGS091LRAA0AAAA system. Rated for 30 amps with a 24-volt control coil, the contactor closes when the thermostat calls for cooling, sending line voltage to the outdoor unit. Over time the contacts pit, burn, and weld from the high inrush current of every compressor start. Common failure symptoms include a unit that won't start, a chattering or buzzing outdoor unit, contacts that stick closed so the compressor never shuts off, or a faint click with no compressor engagement. Replacing a worn contactor is one of the most common and inexpensive HVAC repairs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as the exact OEM replacement for the ICP\/Tempstar\/Heil RGS091LRAA0AAAA. The 30A 2-pole 24V configuration is also used across many comparable ICP-family condensing units and gas furnace blower assemblies — verify your old part is stamped 1178074 or matches the 30A\/2-pole\/24V coil rating before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage across the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's electrical service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire positions on the line, load, and coil terminals before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect each wire, release the mounting screws, and lift out the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly per your photo, confirming the 24V coil leads land on the coil terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contactor pulls in cleanly with no chatter and the compressor\/fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor won't start\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on the old part\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously because the contacts are stuck closed\u003c\/li\u003e\n\u003cli\u003eChattering relay or intermittent cooling on hot days\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027674546547,"sku":"1178074-GEN","price":27.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047909441907,"sku":"1178074","price":35.1,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_8439f015-01f5-4e83-9762-c18d6080f80e.jpg?v=1782879796","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs091lraa0aaaa-30-amp-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}