{"product_id":"icp-2-pole-30a-contactor-for-rgs090stbb0aaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS090STBB0AAA – 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis ICP 2-Pole 30 Amp Contactor (OEM part 1178074) is the electromagnetic relay that switches line voltage to the system's high-draw loads in the ICP \/ Tempstar \/ Heil RGS090STBB0AAA. When the 24V control circuit energizes the coil, the contactor pulls in and closes both poles to deliver power; when the call ends, it drops out and cuts power. Contactors are high-wear components — the contacts erode, pit, and weld over thousands of switching cycles, and the coil can burn open. Failure shows up as a system that won't start, chatters, hums, or refuses to shut off because the contacts have fused closed. This OEM-rated 30A, 2-pole, 24V-coil contactor restores reliable, clean switching.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM fit for the ICP \/ Tempstar \/ Heil RGS090STBB0AAA and matching RGS090 platform units requiring a 2-pole, 30A, 24V-coil contactor. Confirm pole count and coil voltage before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power and verify zero voltage with a multimeter at the contactor terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the electrical control panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Label and disconnect each wire, unscrew the old contactor from its mount.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new 30A contactor and reconnect every wire exactly per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power, initiate a call, and confirm the contactor pulls in cleanly and the loads energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSystem won't start even though the coil is being energized at 24V.\u003c\/li\u003e\n\u003cli\u003eLoud humming, buzzing, or chattering from the contactor.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on the existing unit.\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously and won't shut off (contacts stuck closed).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027680969075,"sku":"1178074-GEN","price":38.0,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047908786547,"sku":"1178074","price":49.4,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_66feab66-0096-4231-a552-5a2bdd29270f.jpg?v=1782879755","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs090stbb0aaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}