{"product_id":"icp-2-pole-30a-contactor-for-rgs090sfaa0akaa-24v-coil-ships-today","title":"ICP 2-Pole 30A Contactor for RGS090SFAA0AKAA - 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM 2-pole definite purpose contactor, part number 1178074, rated 30 amps with a 24-volt coil, for ICP\/Heil\/Tempstar model RGS090SFAA0AKAA. The contactor is an electrically controlled switch: when the thermostat sends a 24V signal, the coil pulls the contacts closed and energizes the compressor and condenser fan motor. Over time the contacts pit, burn, and arc from repeated switching, and the coil can fail open. Symptoms of a failing contactor include a system that won't start, chattering or humming at the contactor, contacts that stick closed and run continuously, or a buzzing coil that won't pull in. Installing a fresh contactor restores clean, reliable switching.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect-fit OEM replacement for ICP, Heil, Tempstar, and Comfortmaker model RGS090SFAA0AKAA and related units originally equipped with contactor 1178074. Verify pole count, amp rating, and 24V coil against your existing contactor before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e - Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e - Remove the control-panel service cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e - Photograph every wire position on the contactor before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e - Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e - Mount the new contactor and reconnect each wire exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e - Restore power and confirm the contactor pulls in on a call for cooling and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSystem fails to start on a cooling call\u003c\/li\u003e\n\u003cli\u003eLoud chattering, humming, or buzzing at the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burnt, or welded contacts that stick closed\u003c\/li\u003e\n\u003cli\u003eCompressor or fan runs continuously and won't shut off\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027683492211,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047908426099,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_241e1d18-69bf-474b-bf1e-1a581b2aa26d.jpg?v=1782879730","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-for-rgs090sfaa0akaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}