{"product_id":"icp-2-pole-30a-contactor-24v-coil-for-rhh060l0ba0aaaa-oem-1178074-ships-today","title":"ICP 2-Pole 30A Contactor 24V Coil for RHH060L0BA0AAAA – OEM 1178074 | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole, 30-amp contactor with a 24V coil (ICP part number 1178074) is the main switching relay for the ICP\/Tempstar\/Heil RHH060L0BA0AAAA heat pump. When the thermostat sends a 24-volt call, the coil pulls the contacts closed and feeds line power to the compressor and condenser fan motor. Because the contacts make and break high current thousands of times per season, they eventually pit, burn, or weld. A failing contactor shows up as a buzzing or chattering sound, an outdoor unit that won't start, a fan or compressor that runs continuously even with the thermostat off (welded contacts), or visible arcing and pitting on the contact faces.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt for the ICP\/Tempstar\/Heil RHH060L0BA0AAAA and other condensing units and heat pumps that use a 2-pole, 30A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage match your old part before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across all contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the service panel to reach the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer wires one at a time or label them, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor, reconnect each wire to the matching terminal per your photo, and tighten lugs to a secure fit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power, place a thermostat call, and confirm the contacts pull in cleanly with no chatter and the unit starts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBuzzing, humming, or chattering at the outdoor unit\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor\/fan runs nonstop or won't start at all\u003c\/li\u003e\n\u003cli\u003e24V coil reads open or out of spec on a meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027264291187,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047259816307,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_2895e52c-2184-4a38-9e96-a8cd22cb097a.jpg?v=1782879645","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-contactor-24v-coil-for-rhh060l0ba0aaaa-oem-1178074-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}