{"product_id":"icp-2-pole-30a-40a-24v-contactor-for-rgs150hdcb0aaaa-oem-definite-purpose-ships-today","title":"ICP 2-Pole 30A\/40A 24V Contactor for RGS150HDCB0AAAA — OEM Definite Purpose | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM 2-pole definite-purpose contactor for the ICP Tempstar Heil RGS150HDCB0AAAA is available in 30 amp (P\/N 1178074) and 40 amp (P\/N 1178211) ratings, both with a 24-volt coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling — the 24V coil pulls in the contacts to pass line voltage to the load. Contactors are one of the most common failure points in HVAC systems: contacts pit, burn, weld closed, or chatter, and coils burn open. A failing contactor shows up as a unit that won't start, won't shut off, or buzzes loudly. Choose the amp rating that matches your original contactor.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074 (30A), 1178211 (40A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A \/ 40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Condenser Fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Genuine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP Tempstar Heil RGS150HDCB0AAAA and related ICP-family condensing units. Match the amp rating (30A or 40A) and 24V coil to your existing contactor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter on both line legs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser control-panel cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time to the new contactor, or unscrew the old contactor from the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, land the line\/load wires on L1-L2 \/ T1-T2 and the 24V coil leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit won't start or won't shut off\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or chattering at the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eBurned-open 24V coil (no pull-in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"Direct Replacement","offer_id":63027431932275,"sku":"1178074-GEN","price":26.95,"currency_code":"USD","in_stock":true},{"title":"OEM","offer_id":63047930839411,"sku":"1178074","price":35.04,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_38c5637c-2b22-4d26-a389-c2a7ca4b057d.jpg?v=1782881197","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-40a-24v-contactor-for-rgs150hdcb0aaaa-oem-definite-purpose-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}