{"product_id":"icp-2-pole-30a-24v-contactor-for-rhs036h0ba0aaaa-definite-purpose-ships-today","title":"ICP 2-Pole 30A 24V Contactor for RHS036H0BA0AAAA — Definite Purpose | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM 2-pole, 30-amp definite purpose contactor (part #1178074) switches line power to the compressor and condenser fan motor on the ICP\/Tempstar\/Heil RHS036H0BA0AAAA condensing unit. A 24V signal from the thermostat\/control board energizes the coil, pulling the contacts closed to start the outdoor unit. Contactors are one of the most common HVAC failure points — the contacts pit, burn, and weld from arcing, while ants and debris can jam the armature. A failed contactor causes a no-cool\/no-heat-pump call, chattering, or a unit that won't shut off.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eFits the ICP RHS036H0BA0AAAA heat pump and many Tempstar, Heil, and Comfortmaker outdoor units specifying a 2-pole 30A 24V coil contactor. Verify pole count and coil voltage against your old part.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time to the new contactor, or label and remove, then unbolt the old unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in on a cooling call with clean, quiet engagement.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start on a thermostat call\u003c\/li\u003e\n\u003cli\u003eLoud humming or chattering at the contactor\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off (stuck closed)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021928677747,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047258866035,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_4b13f064-c865-4253-9fdc-7213a3f173c2.jpg?v=1782879600","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-24v-contactor-for-rhs036h0ba0aaaa-definite-purpose-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}