{"product_id":"icp-2-pole-30a-24v-contactor-for-rgs240sraa0aaaa-definite-purpose-relay-ships-today","title":"ICP 2-Pole 30A 24V Contactor for RGS240SRAA0AAAA — Definite Purpose Relay | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM 2-pole definite purpose contactor (part #1171554) is the high-voltage switching relay for the ICP RGS240SRAA0AAAA. Rated at 30 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V signal reaches the coil, the contactor's magnetic field pulls the contacts closed, sending line voltage to the compressor. Failed contactors are one of the most common no-cool service calls: pitted or welded contacts, a burned-out coil, or a buzzing\/chattering hum that prevents the unit from starting reliably.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1171554\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS240SRAA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits the ICP\/Tempstar\/Heil RGS240SRAA0AAAA gas furnace\/condensing unit and many other ICP-family 2-ton through 5-ton systems that use a 2-pole 30A definite purpose contactor with a 24V coil. Always confirm pole count, amp rating, and coil voltage against the failed part before installing.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel from the condensing unit or control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire positions before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note the line, load, and 24V coil terminals, disconnect each wire, then unscrew the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect every wire exactly as photographed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contacts pull in cleanly with no buzzing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUnit won't start or only starts intermittently on a cooling call\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eVisibly pitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCoil tests open or out of spec on a multimeter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027292111219,"sku":"1171554","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047257260403,"sku":"1171554-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1171554_14ba5476-2e05-433d-b22f-766e68ba6501.jpg?v=1782879513","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-24v-contactor-for-rgs240sraa0aaaa-definite-purpose-relay-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}