{"product_id":"icp-2-pole-30a-24v-contactor-for-rgs150sfba0aaaa-30-amp-definite-purpose-ships-today","title":"ICP 2-Pole 30A 24V Contactor for RGS150SFBA0AAAA — 30 Amp Definite Purpose | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole, 30 amp definite-purpose contactor with a 24-volt coil (part 1178074) is the main switching relay for the ICP\/Tempstar\/Heil RGS150SFBA0AAAA unit. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the two power poles closed to send line voltage to the compressor and condenser fan motor. Contactors are high-wear parts: every cooling cycle arcs the contacts, and over thousands of cycles the points pit, burn, and weld — causing a compressor that won't start, a unit that won't shut off, or chattering and buzzing at the contactor. Replacing a worn 30A contactor restores clean, reliable switching and protects the more expensive compressor and fan motor downstream.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Condenser Fan Switching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eRGS150SFBA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP-family RGS150SFBA0AAAA and related Tempstar, Heil, and Comfortmaker condensing units that use a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker and verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire on the line, load, and coil terminals before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Move wires one at a time to the new contactor, or label them, then unbolt the old contactor from the cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 30A contactor in the same orientation and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the coil pulls in cleanly and the compressor and fan start without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor and fan won't start even though the thermostat is calling.\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering at the contactor.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts that stick closed (unit won't shut off).\u003c\/li\u003e\n\u003cli\u003eVisible arcing, melted housing, or scorched terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027360858483,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047256179059,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_b81c6179-541f-426c-88f7-f0f01a62d49d.jpg?v=1782879451","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-24v-contactor-for-rgs150sfba0aaaa-30-amp-definite-purpose-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}