{"product_id":"icp-2-pole-30a-24v-contactor-for-rgs150lfba0aaaa-oem-ships-today","title":"ICP 2-Pole 30A 24V Contactor for RGS150LFBA0AAAA | OEM | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis is a genuine OEM 2-pole, 30-amp definite purpose contactor with a 24-volt coil, part number 1178074, for the ICP \/ Tempstar \/ Heil RGS150LFBA0AAAA unit. The contactor is the electrically-controlled switch that energizes the condenser fan motor and compressor when the thermostat calls for cooling. Its 24V coil pulls in the contacts to pass line voltage to the load. Contactors fail from pitted or welded contacts, a burned-out coil, or insect\/debris intrusion that blocks the armature — leaving the unit unable to start or unable to shut off.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eEngineered for the ICP RGS150LFBA0AAAA platform and related Tempstar, Heil, and Comfortmaker condensing units using a 2-pole 30A contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your existing part.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical\/control access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label them, then unscrew and remove the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in and the unit energizes cleanly with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUnit won't start, or the contactor chatters\/buzzes.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts.\u003c\/li\u003e\n\u003cli\u003eCompressor or fan won't shut off when the call ends.\u003c\/li\u003e\n\u003cli\u003eHumming coil that fails to pull the contacts in.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027385696627,"sku":"1178074","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047255949683,"sku":"1178074-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_b0639140-0bec-4767-b7cd-dbbfd92f45db.jpg?v=1782879437","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-24v-contactor-for-rgs150lfba0aaaa-oem-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}