{"product_id":"icp-2-pole-30a-24v-contactor-for-rgs091lrba0aaaa-definite-purpose-ships-today","title":"ICP 2-Pole 30A 24V Contactor for RGS091LRBA0AAAA — Definite Purpose | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole, 30-amp definite purpose contactor (P\/N 1178074) with a 24-volt coil is the switching relay that powers the compressor and condenser fan in the ICP RGS091LRBA0AAAA system. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the high-current loads. Contactors are among the most common HVAC failure points: the contacts pit and burn from repeated arcing, and the coil can fail open, leaving the system unable to start. Symptoms include a humming or chattering contactor, contacts that weld closed (system runs continuously), or no compressor operation at all. Replacing a worn contactor restores clean, reliable switching and protects downstream components.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1178074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eRGS091LRBA0AAAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP \/ Tempstar \/ Heil RGS091LRBA0AAAA and other units calling for a 2-pole 30A definite purpose contactor with a 24V coil. Confirm amp rating and coil voltage against the part you are replacing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and verify zero voltage with a multimeter across all terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel to expose the contactor in the control box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, then unfasten the old contactor from its mounting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eLoud humming or chattering when energized\u003c\/li\u003e\n\u003cli\u003eCompressor and fan won't start despite a cooling call\u003c\/li\u003e\n\u003cli\u003eSystem runs continuously because contacts stick closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027674349939,"sku":"1178074","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047248806259,"sku":"1178074-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-1178074_ccc4edad-48e3-4d1d-bc93-f75972e41691.jpg?v=1782879101","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-30a-24v-contactor-for-rgs091lrba0aaaa-definite-purpose-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}