{"product_id":"icp-2-pole-18a-contactor-for-ryb023gaa-24v-coil-ships-today","title":"ICP 2-Pole 18A Contactor for RYB023GAA — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 2-pole definite purpose contactor (part #60126456) is the primary switching device for the ICP RYB023GAA condensing unit. Energized by a 24-volt control signal from the thermostat circuit, its 18-amp rated contacts close to deliver line voltage to the compressor and condenser fan motor. When the contactor fails, the system either will not start or, in the case of welded contacts, will not shut off. Common failure modes include pitted or burned contacts, a chattering or open coil, and insect or debris intrusion that prevents the armature from pulling in cleanly. Replacing a worn contactor restores reliable, clean switching and protects the compressor from low-voltage and short-cycling damage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e60126456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e18 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM replacement for the ICP \/ Tempstar \/ Heil RYB023GAA condensing unit. Also commonly used across matching ICP-family air conditioners and heat pumps that originally shipped with a 2-pole 18A 24V-coil contactor. Always confirm the existing contactor's pole count, amp rating, and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit's service panel to expose the control compartment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and coil wiring before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and disconnect the wires, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo, ensuring the two 24V coil leads are correct.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSystem won't start, or you hear a buzzing\/chattering from the contactor.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit keeps running after the thermostat is satisfied (welded contacts).\u003c\/li\u003e\n\u003cli\u003eVisible pitting, arcing marks, or melted plastic on the contactor body.\u003c\/li\u003e\n\u003cli\u003eIntermittent cooling and short-cycling traced to the control circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021835551091,"sku":"60126456","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047246512499,"sku":"60126456-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-2pole-60126456_50cebb83-5092-42c8-bc57-b120ef751245.jpg?v=1782878973","url":"https:\/\/nationalhvacparts.com\/products\/icp-2-pole-18a-contactor-for-ryb023gaa-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}