{"product_id":"icp-1-pole-contactor-for-wja348000k000a1-40a-24v-coil-ships-today-1","title":"ICP 1-Pole Contactor for WJA348000K000A1 — 40A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM single-pole contactor for the ICP \/ Tempstar \/ Heil \u003cstrong\u003eWJA348000K000A1\u003c\/strong\u003e, OEM part number \u003cstrong\u003e1173690\u003c\/strong\u003e (CONTACTOR 1P 40A 24V). The contactor is the electrically-operated switch that sends high-voltage line power to the compressor and condenser fan motor whenever the 24V control circuit calls for cooling. Rated for 40 amps with a 24V coil, it carries the unit's full running load. Contactors are one of the most common HVAC failure points: the contacts pit and arc over thousands of cycles, and the coil can burn open. A failed contactor leaves the outdoor unit silent on a cooling call, or causes it to chatter, weld closed, or run continuously.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1173690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSingle-Pole (1-Pole) Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM direct replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM replacement for the ICP \/ Tempstar \/ Heil model \u003cstrong\u003eWJA348000K000A1\u003c\/strong\u003e. This 1-pole 40A 24V-coil contactor is a common service part across ICP-family condensing units and heat pumps of similar tonnage. Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the contactor terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the outdoor unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before removing them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time, or label each lead, then unscrew the old contactor from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, land line and load conductors on the correct poles, and reconnect the 24V coil leads per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contactor pulls in cleanly on a cooling call with no chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit does not start on a cooling call but 24V is present at the coil.\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the contactor.\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts that keep the compressor running.\u003c\/li\u003e\n\u003cli\u003eOpen or burned coil reading infinite resistance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027233063283,"sku":"1173690","price":42.9,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047243334003,"sku":"1173690-GEN","price":33.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1173690_31f6917a-f58f-44d3-9358-760b31f42ee5.jpg?v=1782878829","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-contactor-for-wja348000k000a1-40a-24v-coil-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}