{"product_id":"icp-1-pole-contactor-for-wch3422gkr4-30a-24v-coil-ships-today-1","title":"ICP 1-Pole Contactor for WCH3422GKR4 — 30A 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole contactor (part number 1172472) is the primary switching relay for the ICP WCH3422GKR4 heat pump\/condensing unit. Rated at 30 amps with a 24-volt control coil and an integrated shunt, the contactor energizes the compressor and outdoor fan motor each time the thermostat calls for cooling. When the 24V coil receives power, the electromagnet pulls the contacts closed and sends line voltage to the outdoor equipment. Over thousands of cycles the silver-alloy contacts pit, burn, and weld, while the coil can open or short. A failing contactor is one of the most common causes of an outdoor unit that hums but won't start, chatters, or runs continuously even after the thermostat is satisfied. Replacing it restores clean, reliable switching and protects the more expensive compressor from low-voltage damage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM fit for the ICP WCH3422GKR4 outdoor unit and the matching Tempstar, Heil, and Comfortmaker variants built on the same chassis. Always confirm the existing contactor is a 1-pole, 30A, 24V coil unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the electrical access panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note line, load, and 24V coil leads, transfer one wire at a time, then unbolt the old contactor from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contacts.\u003c\/li\u003e\n\u003cli\u003eChattering or rapid clicking when the thermostat calls for cooling.\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously and won't shut off because the contacts have welded closed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027252789619,"sku":"1172472","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047243071859,"sku":"1172472-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_999b6eab-3f58-4bab-8a01-fc00030842a1.jpg?v=1782878816","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-contactor-for-wch3422gkr4-30a-24v-coil-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}