{"product_id":"icp-1-pole-40a-contactor-for-wph3604000rkc1-24v-coil-ships-today","title":"ICP 1-Pole 40A Contactor for WPH3604000RKC1 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole contactor (part number 1173690) is the primary switching relay for the ICP\/Tempstar\/Heil WPH3604000RKC1 heat pump condensing unit. Rated for 40 amps with a 24-volt control coil, the contactor closes when the thermostat calls for cooling or heating, sending line voltage to the compressor and condenser fan motor. When the coil fails, the contacts pit, or the points weld shut, the outdoor unit either will not start or will not shut off. A 1-pole, 40A, 24V contactor is one of the most common HVAC service replacements because the contacts carry full compressor inrush current every cycle.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1173690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirectly fits the ICP\/Tempstar\/Heil\/Comfortmaker WPH3604000RKC1 heat pump. The 1-pole 40A 24V form factor is also a common service replacement across many ICP-family condensing units and heat pumps. Always confirm the original contact rating and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service\/electrical panel on the condensing unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wiring before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note wire positions, disconnect the line and load terminals plus the two coil leads, and unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line, load, and 24V coil wiring exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums but compressor and fan do not start.\u003c\/li\u003e\n\u003cli\u003eContactor points are pitted, burned, or welded together.\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously and will not shut off (stuck contacts).\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering from the contactor when the thermostat calls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021491519859,"sku":"WPH3604000RKC1","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047241236851,"sku":"WPH3604000RKC1-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-WPH3604000RKC1.jpg?v=1782878737","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-40a-contactor-for-wph3604000rkc1-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}