{"product_id":"icp-1-pole-40a-contactor-for-wpg4484130lkb1-24v-coil-ships-today-1","title":"ICP 1-Pole 40A Contactor for WPG4484130LKB1 – 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM definite purpose contactor (part number 1173690) is the factory switching relay for the ICP\/Tempstar\/Heil WPG4484130LKB1. It is a 1-pole contactor rated for 40 amps with a 24V coil. When the thermostat calls for cooling, the 24V coil pulls the contacts closed to send line voltage to the compressor and condenser fan. Contactors wear out from millions of switching cycles, leaving pitted or welded contacts and a chattering or non-pulling coil. A bad contactor causes a unit that won't start, a humming or buzzing outdoor unit, or a compressor that won't shut off because the contacts have welded closed.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1173690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e40A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFit\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacement for the ICP \/ Tempstar \/ Heil WPG4484130LKB1 packaged unit. Verify the pole count, amp rating, and 24V coil voltage against your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the service panel to reach the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph every line, load, and coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer wires one at a time or label them, then unbolt the old contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor and reconnect each wire to the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but won't start\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor won't shut off (stuck closed)\u003c\/li\u003e\n\u003cli\u003eChattering contactor or coil that won't pull in\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027207307635,"sku":"1173690","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047239467379,"sku":"1173690-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1173690_1ace7830-605c-424f-94e6-15e3ca83081e.jpg?v=1782878675","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-40a-contactor-for-wpg4484130lkb1-24v-coil-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}