{"product_id":"icp-1-pole-35a-contactor-for-yg048gc-24v-coil-ships-today","title":"ICP 1-Pole 35A Contactor for YG048GC — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 1-pole definite purpose contactor (part number 1050839) is the main switching relay for the ICP\/Tempstar\/Heil YG048GC heat pump condensing unit. Rated at 35 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. Applying 24V to the coil creates a magnetic field that pulls the contacts closed and delivers line voltage to the load; releasing the coil opens them again. Because a 35A contactor switches heavy current every cycle, all season long, its contacts pit and its coil weakens with age. Common failure symptoms include a unit that won't start, loud buzzing or chattering, contacts that weld closed so the compressor never shuts off, and a coil that won't pull in. Replacing a worn contactor restores clean, full-voltage switching and shields the compressor from low-voltage and short-cycling damage.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050839\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor, 1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e35 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eEngineered as a direct OEM replacement for the ICP\/Tempstar\/Heil YG048GC condensing unit. The 35A \/ 24V rating is common across many ICP-family residential split-system condensers and heat pumps, but always confirm your existing contactor's amp and coil-voltage rating before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service panel to expose the control box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer one wire at a time, or label each lead, then unfasten the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line and load to the correct poles and the 24V leads to the coil terminals per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contacts\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously or won't shut off\u003c\/li\u003e\n\u003cli\u003eUnit fails to start on a cooling\/heating call\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021447643507,"sku":"1050839","price":41.6,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047233732979,"sku":"1050839-GEN","price":32.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050839_0a4d584e-6db5-46a3-8a1d-fb43e26f0067.jpg?v=1782878456","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-35a-contactor-for-yg048gc-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}