{"product_id":"icp-1-pole-30a-contactor-for-wta3362000rka1-24v-coil-w-shunt-ships-today-1","title":"ICP 1-Pole 30A Contactor for WTA3362000RKA1 — 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM ICP contactor (part number 1172472) is a 1-pole, 30-amp definite-purpose contactor with a 24-volt coil and integrated shunt, built for the ICP\/Tempstar\/Heil WTA3362000RKA1 condensing unit. The contactor is the electrical switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V control signal hits the coil, the magnetic field pulls the contacts closed and delivers line voltage to the outdoor unit. Over time the contacts pit, arc, and weld from repeated switching, and the coil can burn open — leaving you with a unit that hums but won't start, or one that runs continuously because the contacts have fused shut. Replacing a worn contactor is one of the most common and inexpensive condenser repairs.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIntegrated Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eWTA3362000RKA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eDirect OEM fit for the ICP\/Tempstar\/Heil WTA3362000RKA1 condensing unit. This 1-pole, 30A, 24V-coil contactor is also used across many comparable ICP-family residential air conditioners and heat pumps. Always confirm the existing part number (1172472) and coil voltage before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser service\/access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all wire positions on the old contactor before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note line, load, and 24V coil wiring, then transfer the leads one at a time off the old contactor; unscrew it from the mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm the 24V coil leads are secure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contacts pull in and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit hums or buzzes but the compressor and fan won't start.\u003c\/li\u003e\n\u003cli\u003eVisible pitting, burning, or melted plastic on the contactor body or terminals.\u003c\/li\u003e\n\u003cli\u003eContacts stuck closed — the unit keeps running after the thermostat is satisfied.\u003c\/li\u003e\n\u003cli\u003eChattering or intermittent cooling caused by a weak or failing 24V coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027202392435,"sku":"1172472","price":36.34,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047231897971,"sku":"1172472-GEN","price":27.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_81f4f4a9-9ee0-4d62-bec3-75166f18fcc1.jpg?v=1782878371","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-30a-contactor-for-wta3362000rka1-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}