{"product_id":"icp-1-pole-30a-contactor-for-wpg4424090lkb1-24v-coil-w-shunt-ships-today-1","title":"ICP 1-Pole 30A Contactor for WPG4424090LKB1 — 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis genuine OEM single-pole contactor (part number 1172472) is the primary switching relay for the ICP \/ Tempstar \/ Heil WPG4424090LKB1 package unit. Rated 30 amps with a 24-volt coil and an integrated shunt, it energizes the compressor and condenser fan whenever the thermostat calls for cooling. The 24V control signal pulls in the contactor, closing the high-voltage contacts that feed the outdoor unit. The built-in shunt provides a defined current path for the auxiliary circuit. Contactor contacts wear, pit, and burn over time from the arc generated on every start and stop, which is one of the most common reasons a condenser will hum but fail to start.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1-Pole Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eIncludes Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacement for the WPG4424090LKB1 and many other ICP, Tempstar, Heil, and Comfortmaker condensing and package units that use a 30A 1-pole 24V contactor. Verify amp rating, pole count, and coil voltage against your existing part.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and disconnect, then confirm zero voltage at the line terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every wire and terminal position before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, then unscrew the old contactor from the panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect line, load, and 24V coil wires exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCondenser hums but the compressor and fan will not start\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts\u003c\/li\u003e\n\u003cli\u003eBuzzing or chattering when the unit calls for cooling\u003c\/li\u003e\n\u003cli\u003eContacts that stick closed and keep the unit running\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027209306483,"sku":"1172472","price":42.84,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047230783859,"sku":"1172472-GEN","price":32.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_aa497e0f-d4ea-4a4c-83a3-5509d937bbad.jpg?v=1782878327","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-30a-contactor-for-wpg4424090lkb1-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}