{"product_id":"icp-1-pole-30a-contactor-for-wpg4364090lkb1-24v-coil-w-shunt-ships-today-1","title":"ICP 1-Pole 30A Contactor for WPG4364090LKB1 — 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis is the OEM 1-pole, 30-amp contactor with a 24V coil and integrated shunt (part number 1172472) for the ICP \/ Tempstar \/ Heil WPG4364090LKB1 packaged unit. The contactor is the high-current switch that energizes the compressor and outdoor fan whenever the 24V control circuit calls for cooling. When the thermostat closes, 24V pulls the coil in and the contacts pass line voltage to the load; the shunt provides a continuous power path for the crankcase heater or accessory circuit even when the contacts are open. Contacts pit, weld, and burn over time, leading to a compressor that won't start, chatters, or runs continuously. This direct-fit OEM contactor restores clean, reliable switching.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeature\u003c\/td\u003e\n\u003ctd\u003eIntegrated Shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eAC Compressor \/ Condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eBuilt as the factory contactor for the ICP WPG4364090LKB1 and equivalent Tempstar, Heil, and Comfortmaker packaged units on this platform. Confirm pole count, contact amp rating, coil voltage, and shunt configuration against your existing contactor before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the unit and breaker, then verify zero voltage with a multimeter at the contactor line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the control \/ service panel to reach the contactor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, coil, and shunt connection before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Label and remove the wires, then unbolt the burned or pitted contactor from the mounting rail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 1-pole contactor, land the line and load conductors, and connect the 24V coil leads and shunt exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly with the compressor and fan starting normally.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCompressor and condenser fan won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003eBuzzing, chattering, or contactor that won't pull in\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or welded contacts\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously because the contacts are stuck closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027211305331,"sku":"1172472","price":44.14,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047230292339,"sku":"1172472-GEN","price":33.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_67af1954-2e45-4e8d-8012-561467b6b710.jpg?v=1782878300","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-30a-contactor-for-wpg4364090lkb1-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}