{"product_id":"icp-1-pole-30a-contactor-for-wja324000ktp0a2-24v-coil-w-shunt-ships-today-1","title":"ICP 1-Pole 30A Contactor for WJA324000KTP0A2 – 24V Coil w\/ Shunt | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM single-pole 30-amp definite purpose contactor (part 1172472) is the line-voltage switch for the ICP \/ Tempstar \/ Heil WJA324000KTP0A2 unit. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. The integrated shunt provides the correct internal jumper for this unit's wiring. Contactors are one of the most common failure points in an outdoor unit: the contacts pit, burn, and weld from constant arcing, and the coil can fail open so it no longer pulls in. Symptoms include a humming or chattering contactor, a unit that will not start, or contacts that stick closed and keep the compressor running.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1172472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1-Pole (single-pole) definite purpose contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e30 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeatures\u003c\/td\u003e\n\u003ctd\u003eIncludes shunt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Tempstar \/ Heil \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Genuine Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFactory-correct 1-pole, 30A, 24V contactor with shunt for the ICP unit WJA324000KTP0A2 and related Tempstar, Heil, and Comfortmaker condensing units using the same switching arrangement. Confirm your model and serial number on the rating plate before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e – Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter across the line terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e – Remove the condenser service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e – Photograph every line-voltage and 24V coil wire before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e – Transfer one wire at a time, or label leads, then unbolt the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e – Mount the new contactor, confirm the shunt is in place, and reconnect the line and 24V coil wires exactly per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e – Restore power and verify the coil pulls the contacts in on a cooling call and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHumming, buzzing, or chattering contactor that will not stay pulled in\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on inspection\u003c\/li\u003e\n\u003cli\u003eUnit will not start even with a confirmed 24V signal at the coil\u003c\/li\u003e\n\u003cli\u003eCompressor keeps running because the contacts are stuck closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63027235619187,"sku":"1172472","price":35.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047224230259,"sku":"1172472-GEN","price":26.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1172472_a5096fdb-f75b-4606-92e4-c7c969061989.jpg?v=1782878068","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-30a-contactor-for-wja324000ktp0a2-24v-coil-w-shunt-ships-today-1","provider":"National HVAC Parts","version":"1.0","type":"link"}