{"product_id":"icp-1-pole-25a-contactor-for-yk042gc2-24v-coil-ships-today","title":"ICP 1-Pole 25A Contactor for YK042GC2 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis OEM 1-pole, 25-amp contactor (part #1050699) with a 24V coil is the high-voltage switch that powers up the compressor and condenser fan on your ICP\/Tempstar\/Heil YK042GC2 unit. When the thermostat calls, the 24V coil pulls the contacts closed to feed line voltage to the outdoor components. Over time the contacts pit, burn, weld, or chatter, and the coil can fail open. Symptoms include the outdoor unit not starting, a buzzing or humming contactor, the unit running nonstop because the contacts welded shut, or visibly pitted and blackened contacts. This direct OEM replacement restores reliable, clean switching.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003e1-Pole Definite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Tempstar \/ Heil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eFits the ICP Tempstar Heil YK042GC2 and related ICP-family condensing units that originally used OEM contactor 1050699. Confirm pole count, amp rating, and 24V coil before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condensing unit service panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Move the wires one at a time to the new contactor, then unmount the old one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new 25A contactor and confirm each line, load, and 24V coil lead matches your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and verify the contactor pulls in on a cooling call and the compressor and fan start.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor unit won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003eLoud buzzing or humming from the contactor\u003c\/li\u003e\n\u003cli\u003eContacts are pitted, burned, or welded shut\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021439058291,"sku":"1050699","price":35.04,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047214563699,"sku":"1050699-GEN","price":26.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050699_f28b0c98-8821-47eb-8b86-2edbeea83366.jpg?v=1782877588","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-25a-contactor-for-yk042gc2-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}