{"product_id":"icp-1-pole-25a-contactor-for-yk018gc2-24v-coil-ships-today","title":"ICP 1-Pole 25A Contactor for YK018GC2 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe ICP 1-pole 25-amp contactor (OEM #1050699) is the electrically operated switch that powers the compressor and condenser fan in your ICP\/Heil\/Tempstar YK018GC2. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor; when the call ends, the contacts open. Over time the contact points pit, burn, and weld from arcing, while the 24V coil can fail open. A bad contactor is a leading cause of a condenser that won't start, hums without running, or won't shut off.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRating\u003c\/td\u003e\n\u003ctd\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP (Heil \/ Tempstar \/ Comfortmaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM replacement for the ICP YK018GC2 and other ICP-family condensing units (Heil, Tempstar, Comfortmaker) using a 1-pole 25A contactor with a 24V coil. Verify pole count, amp rating, and 24V coil before ordering.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power and verify zero voltage with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the condenser electrical panel cover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires off the old contactor one at a time, then unscrew it from the bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and land each wire on the matching terminal per your photo.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power and confirm the contacts pull in and the compressor starts on a cooling call.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCondenser hums but compressor won't start\u003c\/li\u003e\n\u003cli\u003eBurned, pitted, or welded contact points\u003c\/li\u003e\n\u003cli\u003eUnit won't shut off (contacts stuck closed)\u003c\/li\u003e\n\u003cli\u003e24V coil reads open — no pull-in on a cooling call\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021440008563,"sku":"1050699","price":32.44,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047214268787,"sku":"1050699-GEN","price":24.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050699_8356e6eb-dfea-4766-a726-475532bcec0f.jpg?v=1782877575","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-25a-contactor-for-yk018gc2-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}