{"product_id":"icp-1-pole-25a-contactor-for-yg042ga1-24v-coil-ships-today","title":"ICP 1-Pole 25A Contactor for YG042GA1 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThis OEM single-pole, 25-amp definite purpose contactor (ICP part number 1050699) is the electrical switch that powers the compressor and condenser fan on your ICP \/ Heil \/ Tempstar YG042GA1 unit. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor; when the call ends, the contacts open. Contactors are high-wear items — the contact points pit and burn over thousands of cycles, eventually welding shut or failing to close. A failed contactor is one of the most common no-cool service calls.\u003c\/p\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1050699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eContactor 1P 25A 24V S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e25 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cp\u003eDirect OEM-fit replacement for the ICP \/ Heil \/ Tempstar YG042GA1 condensing unit. The 1050699 1-pole 25A \/ 24V contactor is widely used across ICP-family condensers and heat pumps; confirm pole count, amp rating, and 24V coil voltage match your existing contactor before installing.\u003c\/p\u003e\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the breaker and disconnect, then verify zero voltage at the contactor terminals with a multimeter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the unit's electrical access panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph every line, load, and 24V coil wire before disconnecting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Transfer wires one at a time or label them, unscrew the contactor from the bracket, and lift it out.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, reconnect all wires exactly per your photo, and confirm the coil leads land on the 24V terminals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and verify the contactor pulls in and the compressor and fan energize.\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSystem won't start even though the thermostat is calling for cooling.\u003c\/li\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the contactor.\u003c\/li\u003e\n\u003cli\u003eCompressor runs continuously and won't shut off (contacts welded closed).\u003c\/li\u003e\n\u003cli\u003ePitted, blackened, or burned contact points on inspection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021449576819,"sku":"1050699","price":35.1,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047212892531,"sku":"1050699-GEN","price":27.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-1050699_94a17563-cb35-4896-bd64-2f71f326a4c7.jpg?v=1782877524","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-25a-contactor-for-yg042ga1-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}