{"product_id":"icp-1-pole-23a-contactor-for-ya030-24v-coil-ships-today","title":"ICP 1-Pole 23A Contactor for YA030 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM single-pole definite-purpose contactor (part number 14306505) is the primary switching relay for the ICP\/Heil\/Tempstar YA030 condensing unit. Rated at 23 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heat-pump operation. The 24V coil pulls in a set of heavy-duty silver-alloy contacts that carry line voltage to the outdoor components. Over thousands of cycles these contacts pit, burn, and weld from arcing, while the coil itself can open or weaken. A failed contactor is one of the most common no-cool service calls — symptoms include a buzzing or chattering outdoor unit, a compressor that won't start, contacts that stick closed and run the unit non-stop, or no response at all from the condenser when the system calls for cooling.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e14306505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1 (Single-Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e23 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eYA030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis contactor is the factory-specified switching relay for the ICP YA030 outdoor unit and the equivalent Heil, Tempstar, and Comfortmaker badged versions of the same platform. It is a direct, plug-in OEM replacement — no rewiring or adapters required. Always confirm your existing contactor is a single-pole, 23A, 24V coil unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter before touching any wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel from the condensing unit to expose the contactor and control wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note wire positions, disconnect the spade and lug terminals, then unscrew the old contactor from its mounting bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor, then reconnect each wire to the matching terminal exactly per your photo (line in, load out, 24V on the coil terminals).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan energize without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eCompressor and condenser fan won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts visible on the old part\u003c\/li\u003e\n\u003cli\u003eUnit runs continuously because contacts are stuck closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021459308915,"sku":"14306505","price":37.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047210795379,"sku":"14306505-GEN","price":28.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-14306505_0a9ac0c1-55ad-48cb-9ab9-e92cf5740075.jpg?v=1782877440","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-23a-contactor-for-ya030-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}