{"product_id":"icp-1-pole-23a-contactor-for-ya024-24v-coil-ships-today","title":"ICP 1-Pole 23A Contactor for YA024 — 24V Coil | Ships Today","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThis genuine OEM single-pole definite-purpose contactor (part number 14306505) is the primary switching relay for the ICP\/Heil\/Tempstar YA024 condensing unit. Rated at 23 amps with a 24-volt control coil, it energizes the compressor and condenser fan motor on every call for cooling or heat-pump operation. The 24V coil pulls a set of silver-alloy contacts closed to deliver line voltage to the outdoor components. After tens of thousands of cycles, those contacts pit, arc, and can weld shut, while the coil can open or weaken. A failing contactor is among the most common no-cool service calls — typical symptoms include a buzzing or chattering outdoor unit, a compressor that won't start, contacts stuck closed so the unit never shuts off, or a completely unresponsive condenser.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e14306505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eDefinite-Purpose Contactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICP \/ Heil \/ Tempstar \/ Comfortmaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePoles\u003c\/td\u003e\n\u003ctd\u003e1 (Single-Pole)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Rating\u003c\/td\u003e\n\u003ctd\u003e23 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFits Model\u003c\/td\u003e\n\u003ctd\u003eYA024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFitment\u003c\/td\u003e\n\u003ctd\u003eOEM Direct Replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eThis contactor is the factory-specified switching relay for the ICP YA024 outdoor unit and the equivalent Heil, Tempstar, and Comfortmaker badged versions of the same platform. It is a direct, plug-in OEM replacement — no rewiring or adapters required. Confirm your existing contactor is a single-pole, 23A, 24V coil unit before installing.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety First\u003c\/strong\u003e — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter before touching wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess\u003c\/strong\u003e — Remove the service panel from the condensing unit to expose the contactor and control wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocument\u003c\/strong\u003e — Photograph all line, load, and 24V coil wires before disconnecting anything.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemove\u003c\/strong\u003e — Note wire positions, disconnect the spade and lug terminals, then unscrew the old contactor from its bracket.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall\u003c\/strong\u003e — Mount the new contactor and reconnect each wire to the matching terminal per your photo (line in, load out, 24V on the coil).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest\u003c\/strong\u003e — Restore power, call for cooling, and confirm the contactor pulls in cleanly with the compressor and fan running without chatter.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eSigns You Need a Replacement\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoud buzzing, humming, or chattering from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eCompressor and condenser fan won't start on a cooling call\u003c\/li\u003e\n\u003cli\u003ePitted, burned, or welded contacts on the old part\u003c\/li\u003e\n\u003cli\u003eUnit runs non-stop because contacts are stuck closed\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eShipping \u0026amp; Returns\u003c\/h3\u003e\n\u003cp\u003eShips same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.\u003c\/p\u003e","brand":"ICP","offers":[{"title":"OEM","offer_id":63021459341683,"sku":"14306505","price":37.64,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":63047210762611,"sku":"14306505-GEN","price":28.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-1pole-14306505_93982b51-ef2d-4423-bf04-6c1ab8fe75bc.jpg?v=1782877438","url":"https:\/\/nationalhvacparts.com\/products\/icp-1-pole-23a-contactor-for-ya024-24v-coil-ships-today","provider":"National HVAC Parts","version":"1.0","type":"link"}