{"product_id":"carrier-tcaccycrlpelev006a00-pressure-switch-jesotu","title":"OEM Carrier LP Gas Pressure Switch HK02LB008 — TCACCYCRLPELEV006A00","description":"\u003ch1\u003eOEM Carrier LP Gas Pressure Switch HK02LB008 for Model TCACCYCRLPELEV006A00\u003c\/h1\u003e\u003cp\u003eThis is the factory OEM LP (liquid propane) gas pressure switch for the \u003cstrong\u003eCarrier TCACCYCRLPELEV006A00\u003c\/strong\u003e. The gas pressure switch monitors incoming LP gas supply pressure and proves safe operating pressure before allowing ignition to proceed. When supply pressure falls below or exceeds the factory set-point, the switch opens the control circuit and sends the system into a no-heat lockout condition. Common symptoms of failure include a furnace that attempts ignition but immediately locks out, an error code indicating pressure fault, or a unit that runs the inducer motor but never advances to the ignition stage. \u003cstrong\u003eNote:\u003c\/strong\u003e OEM part HK02LB008 has been discontinued by Carrier; direct OEM successor is HK02MB008. Stock of HK02LB008 remains available — order today while supplies last.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e LP (Liquid Propane) gas pressure switch | Cut-out pressure: 6.5 in W.C. | Factory-matched set-point | OEM part number: HK02LB008 | Manufacturer: Carrier (United Technologies)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM switch — factory-calibrated to the exact 6.5 in W.C. set-point required by the TCACCYCRLPELEV006A00. Aftermarket pressure switches frequently carry wider tolerances, risking nuisance lockouts or unsafe operation on LP systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall difficulty: 2\/5\u003c\/strong\u003e — Shut off gas supply and power to the unit before beginning. Tools needed: 1\/4\" nut driver, flathead screwdriver, manometer (recommended for LP verification). Photograph all wiring connections and hose port routing before removal. The switch is typically secured with one screw and connected via a 1\/4\" hose barb to the burner manifold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty \u0026amp; Shipping:\u003c\/strong\u003e 1-year OEM factory warranty. Orders placed before cutoff ship same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for Carrier model \u003cstrong\u003eTCACCYCRLPELEV006A00\u003c\/strong\u003e LP gas heating equipment. Always verify your unit's data plate fuel type (LP vs. natural gas) and existing switch set-point before ordering — LP and natural gas pressure switches are \u003cem\u003enot\u003c\/em\u003e interchangeable. Questions about fitment? Our HVAC parts specialists verify compatibility before you order — contact us before purchasing.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640287482227,"sku":"CARRIE-TCACCYCRLPELEV006A00-PRESSURE_SWITCH-HK02LB008","price":73.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640287514995,"sku":"CARRIE-TCACCYCRLPELEV006A00-PRESSURE_SWITCH-HK02LB008-GEN","price":64.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-pressure-switch-HK02LB008_637f0e87-21f0-4c49-b647-a77ab1bddd49.jpg?v=1775036495","url":"https:\/\/nationalhvacparts.com\/products\/carrier-tcaccycrlpelev006a00-pressure-switch-jesotu","provider":"National HVAC Parts","version":"1.0","type":"link"}