{"product_id":"carrier-py2ppb048090ab-contactor-1h36kh","title":"OEM Carrier 2-Pole Contactor 30A 24V Coil for PY2PPB048090AB","description":"\u003ch1\u003eOEM Carrier 2-Pole Contactor 30 Amp 24V for Model PY2PPB048090AB (HN52KC025 \/ HN52KC024)\u003c\/h1\u003e\u003cp\u003eThis OEM contactor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY2PPB048090AB\u003c\/strong\u003e packaged unit. The contactor acts as the high-voltage relay that controls power to the compressor and condenser fan motor. When the thermostat calls for cooling, the 24V control circuit energizes the contactor coil, closing the high-voltage contacts and allowing 240V to flow to the compressor. A failed contactor is one of the most common reasons an air conditioner won't turn on — symptoms include a clicking sound with no compressor start, a welded\/fused contact causing the unit to run non-stop, or visible pitting and burning on the contact faces.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole (Double Pole) | 30 Amp FLA | 24V AC Coil | 600V rated | Definite Purpose Contactor | Replaces OEM Part # HN52KC025 (superseded by HN52KC024)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM contactors use silver-alloy contact faces rated to factory specifications for arc suppression and contact life. Generic contactors often use lower-grade alloys that pit faster under load, leading to premature failure and potential compressor damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Shut off power at the disconnect and breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph wiring before disconnecting terminals. Discharge any capacitors in the unit before working nearby.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003ePY2PPB048090AB\u003c\/strong\u003e packaged unit. Note that OEM part number HN52KC025 has been superseded by HN52KC024 — this listing ships the current OEM production replacement. Verify pole count, amperage, and coil voltage on your unit's data plate before ordering. Have a question about fitment? Our HVAC parts specialists verify compatibility before you buy — reach out today and we'll ship your part the same business day.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640507814259,"sku":"CARRIE-PY2PPB048090AB-CONTACTOR-HN52KC025","price":33.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640507847027,"sku":"CARRIE-PY2PPB048090AB-CONTACTOR-HN52KC025-GEN","price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN52KC025_06d5f989-a49d-4139-9381-6e1114bc315b.jpg?v=1775015499","url":"https:\/\/nationalhvacparts.com\/products\/carrier-py2ppb048090ab-contactor-1h36kh","provider":"National HVAC Parts","version":"1.0","type":"link"}