{"product_id":"carrier-py2ppb030060ab-contactor-1h36kh","title":"OEM Carrier 2-Pole Contactor 30A 24V for PY2PPB030060AB — HN52KC025","description":"\u003ch1\u003eOEM Carrier 2-Pole Contactor 30 Amp 24V Coil for Model PY2PPB030060AB — HN52KC025\u003c\/h1\u003e\u003cp\u003eThis OEM 2-pole contactor is the factory-specified replacement for the \u003cstrong\u003eCarrier PY2PPB030060AB\u003c\/strong\u003e packaged unit. The contactor acts as the high-voltage relay that receives a 24V signal from the thermostat or control board and switches line-voltage power (240V) to the compressor and condenser fan motor. When a contactor fails, the most common symptom is an AC system that simply won't turn on — the unit may hum at the contactor but the compressor and fan remain dead. Worn or pitted contacts can also cause intermittent operation, hard starting, or premature compressor failure.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole (Double Pole) | 30 Amp RES \/ 20 Amp FLA | 24VAC coil voltage | 50\/60Hz | Tyco Electronics platform — factory-matched for Carrier equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e OEM contactors use silver-alloy contact tips rated to factory tolerances, delivering consistent arc suppression and longer service life. Generic units often use lower-grade contact materials that pit and weld prematurely, risking compressor damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Shut off all power at the disconnect and breaker before proceeding. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Always photograph wiring connections before removing the old contactor. Discharge any capacitors in the panel before working nearby.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty. In stock and ships same business day from our warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the \u003cstrong\u003eCarrier PY2PPB030060AB\u003c\/strong\u003e packaged unit. Note: OEM part number HN52KC025 has been superseded by HN52KC024 — this listing ships the current factory-authorized replacement. Also fits many Carrier, Bryant, and Payne systems using a 2-pole 30A 24V contactor. Verify pole count, amperage, and coil voltage against your unit's wiring diagram before ordering. Our team is available to confirm fitment before you buy.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62640521642355,"sku":"CARRIE-PY2PPB030060AB-CONTACTOR-HN52KC025","price":33.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62640521675123,"sku":"CARRIE-PY2PPB030060AB-CONTACTOR-HN52KC025-GEN","price":29.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN52KC025_45ac0f81-db15-4535-89c8-f648c26e36fa.jpg?v=1775015521","url":"https:\/\/nationalhvacparts.com\/products\/carrier-py2ppb030060ab-contactor-1h36kh","provider":"National HVAC Parts","version":"1.0","type":"link"}