{"product_id":"carrier-ph13nr04800gaaaa-contactor-1iwxlq","title":"OEM Carrier Contactor 2-Pole 24V Coil for PH13NR04800GAAAA","description":"\u003ch1\u003eOEM Carrier Contactor 2-Pole 24V Coil for Model PH13NR04800GAAAA\u003c\/h1\u003e\u003cp\u003eThis OEM contactor (part number \u003cstrong\u003eHN51KC024\u003c\/strong\u003e) is the factory-specified replacement for the \u003cstrong\u003eCarrier PH13NR04800GAAAA\u003c\/strong\u003e heat pump \/ condensing unit. The contactor is a high-voltage relay that acts as the main power switch for your system — when the thermostat calls for cooling or heating, the 24V control circuit energizes the contactor coil, closing the high-voltage contacts and sending line voltage to the compressor and condenser fan motor. A failed contactor is one of the most common causes of an air conditioning system that won't turn on, hums without starting, or runs continuously without shutting off.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 2-Pole design | 24V AC coil voltage | Factory-rated amperage matched to OEM specification | Direct drop-in replacement for Carrier OEM part HN51KC024\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This OEM contactor uses factory-grade contact materials and coil windings that meet exact Carrier tolerances. Generic contactors may use lower-grade contact alloys, leading to premature pitting, arcing, and compressor damage over time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 2\/5\u003c\/strong\u003e — Always disconnect and lock out power at the breaker before beginning. Tools needed: flathead and Phillips screwdrivers, needle-nose pliers, multimeter. Photograph all wiring before disconnecting. Replacement typically takes 20–30 minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. In-stock and ships same business day from our NationalHVACParts.com warehouse.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Designed for the Carrier \u003cstrong\u003ePH13NR04800GAAAA\u003c\/strong\u003e 4-ton heat pump condensing unit. Always verify coil voltage and pole configuration on your unit's data plate before ordering. Not sure it fits? Our HVAC parts specialists are available to confirm fitment before you buy — same-day shipping on all in-stock orders.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62641857560947,"sku":"CARRIE-PH13NR04800GAAAA-CONTACTOR-HN51KC024","price":68.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62641857593715,"sku":"CARRIE-PH13NR04800GAAAA-CONTACTOR-HN51KC024-GEN","price":60.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-contactor-HN51KC024_e94d3e03-d630-4f3a-9447-4f5089b73a42.jpg?v=1775021737","url":"https:\/\/nationalhvacparts.com\/products\/carrier-ph13nr04800gaaaa-contactor-1iwxlq","provider":"National HVAC Parts","version":"1.0","type":"link"}