{"product_id":"carrier-ph13nb06100gbbaa-fan-motor-1q1yhf","title":"OEM Carrier Condenser Fan Motor 1\/4 HP 825 RPM — PH13NB06100GBBAA","description":"\u003ch1\u003eOEM Carrier Condenser Fan Motor 1\/4 HP 825 RPM for Model PH13NB06100GBBAA (HC39GE242 \/ HB39GQ232)\u003c\/h1\u003e\u003cp\u003eThis is the factory-specified OEM condenser fan motor for the \u003cstrong\u003eCarrier PH13NB06100GBBAA\u003c\/strong\u003e split-system heat pump. The condenser fan motor drives the outdoor fan blade that pulls air across the condenser coil to reject heat. When this motor fails, the outdoor unit will run with no airflow, causing the compressor to overheat and trip on high-pressure lockout — or the condenser fan simply won't spin at all. Common failure symptoms include: outdoor fan not turning, system short-cycling on a hot day, or a humming sound from the condenser cabinet with no blade movement.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecs:\u003c\/strong\u003e 1\/4 HP | 208–230V | 60 Hz | 1.2 Amps | 825 RPM | 48Y Frame | Single Phase | Clockwise Rotation (shaft-end up) | 1.75\" Shaft | Closed Enclosure | OEM Part# HC39GE242 \/ Current Replacement: HB39GQ232 | GE Genteq Model 5KCP39LFY534AS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM vs Generic:\u003c\/strong\u003e This is a genuine Carrier OEM motor matched to the exact HP, RPM, frame, and rotation spec from the factory. Generic aftermarket motors may vary in shaft tolerance, thermal overload calibration, and bearing grade — all of which shorten service life, especially in high-ambient outdoor environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall Difficulty: 3\/5\u003c\/strong\u003e — Disconnect power at the breaker and capacitor before touching any motor terminals. Tools needed: 5\/16\" and 3\/8\" nut drivers, wire stripper, multimeter, belly-band clamp tool. Always photograph all wiring before disconnecting. Note: It is strongly recommended to replace the run capacitor at the same time — a weak capacitor is a leading cause of motor failure and will shorten the life of a new motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1-year OEM factory warranty against defects. Ships same business day from our warehouse when ordered before 3 PM local time.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Fits Carrier model \u003cstrong\u003ePH13NB06100GBBAA\u003c\/strong\u003e and related PH13NB-series heat pump condensers using the HC39GE242 \/ HB39GQ232 motor specification. Also cross-references Bryant and Payne models sharing this platform. Verify HP, RPM, voltage, and rotation on your unit's data plate before ordering. Not sure? Our fitment team verifies compatibility before your order ships — contact us anytime.\u003c\/p\u003e","brand":"Carrier","offers":[{"title":"OEM","offer_id":62641896849779,"sku":"CARRIE-PH13NB06100GBBAA-FAN_MOTOR-HC39GE242","price":296.95,"currency_code":"USD","in_stock":true},{"title":"Generic","offer_id":62641896882547,"sku":"CARRIE-PH13NB06100GBBAA-FAN_MOTOR-HC39GE242-GEN","price":260.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0984\/1190\/5395\/files\/nhvac-fan-motor-HC39GE242_05cde248-0cfe-4b35-aecf-19efa24e3857.jpg?v=1775019398","url":"https:\/\/nationalhvacparts.com\/products\/carrier-ph13nb06100gbbaa-fan-motor-1q1yhf","provider":"National HVAC Parts","version":"1.0","type":"link"}